You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT JAMA
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 286 No. 7, August 15, 2001 TABLE OF CONTENTS
  JAMA
  •  Online Features
  Original Contribution
 This Article
 •Full text
 •PDF
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Citing articles on Web of Science (60)
 •Contact me when this article is cited
 Related Content
 •Related letter
 •Related articles
 •Similar articles in JAMA
 Topic Collections
 •Pacemakers/ Defibrillators
 •Cardiovascular System
 •Quality of Care
 •Patient Safety/ Medical Error
 •Arrhythmias
 •Alert me on articles by topic
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

Recalls and Safety Alerts Involving Pacemakers and Implantable Cardioverter-Defibrillator Generators

William H. Maisel, MD,MPH; Michael O. Sweeney, MD; William G. Stevenson, MD; Kristin E. Ellison, MD; Laurence M. Epstein, MD

JAMA. 2001;286:793-799.

Context  Unanticipated pacemaker and implantable cardioverter-defibrillator (ICD) generator malfunctions sometimes warrant recall by the US Food and Drug Administration (FDA). Despite increasingly frequent device implantation, pacemaker and ICD recalls and safety alerts (advisories) remain poorly characterized.

Objectives  To determine pacemaker and ICD generator advisory rates in the United States, to identify trends in these rates, and to examine their clinical and financial implications.

Design and Setting  Analysis of weekly FDA Enforcement Reports issued between January 1990 and December 2000 to identify all advisories involving pacemaker or ICD generators in the United States. Recalls and safety alerts involving lead malfunctions were not included.

Main Outcome Measures  Number of pacemakers and ICD generators in the United States subject to FDA recall or safety alert in 1990-2000; annual pacemaker and ICD advisory rates in the United States in 1990-2000; and estimated cost of device advisories.

Results  During the study period, 52 advisories (median [25th and 75th percentiles], 4 [4 and 7] per year) involving 408 500 pacemakers and 114 645 ICDs (523 145 total devices) were issued. Hardware malfunctions (35 advisories affecting 280 641 devices) and computer errors (10 advisories affecting 216 533 devices) accounted for 95% of device recalls. Implantable cardioverter-defibrillators were recalled more frequently than pacemakers (mean [SD], 16.4 [1.6] vs 6.7 [0.8] advisories per 100 person-years; P<.001). Between 1995 and 2000, the annual advisory rate increased for both pacemakers (P for trend <.001) and ICDs (P for trend = .02). An estimated 1.3 million device checks and analyses and 36 187 device replacements resulted from the advisories and cost approximately $870 million.

Conclusions  Pacemaker and ICD recalls and safety alerts occur frequently, affect many patients, and appear to be increasing in number and rate. With the growing number of device implants and expanding indications for device therapy, the number of patients affected by device advisories will likely continue to increase.


Author Affiliations: Cardiac Arrhythmia Service, Cardiovascular Division, Department of Medicine, Brigham and Women's Hospital, Boston, Mass.



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter     What's this?

RELATED LETTER

Safety of Implantable Cardiac Devices
Marshall S. Stanton, William H. Maisel, William G. Stevenson, Laurence M. Epstein, and Kim A. Eagle
JAMA. 2002;287(7):839-840.
EXTRACT | FULL TEXT  

RELATED ARTICLES

Safety Alerts Involving Device Therapy for Arrhythmias
Kim A. Eagle
JAMA. 2001;286(7):843-844.
EXTRACT | FULL TEXT  

August 15, 2001
JAMA. 2001;286(7):863-864.
EXTRACT | FULL TEXT  

Heart Pacemakers
JAMA. 2001;286(7):878.
PDF  


THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Are complications of implantable defibrillators under-estimated and benefits over-estimated?
Brignole
Europace 2009;11:1129-1133.
FULL TEXT  

Pacemaker dependency after implantation of electrophysiological devices
Korantzopoulos et al.
Europace 2009;11:1151-1155.
ABSTRACT | FULL TEXT  

Diffusion Of New Technology And Payment Policies: Coronary Stents
Shih and Berliner
Health Aff (Millwood) 2008;27:1566-1576.
ABSTRACT | FULL TEXT  

A Critical Appraisal of Implantable Cardioverter-Defibrillator Therapy for the Prevention of Sudden Cardiac Death
Tung et al.
J Am Coll Cardiol 2008;52:1111-1121.
ABSTRACT | FULL TEXT  

Automatic home monitoring of implantable cardioverter defibrillators
Nielsen et al.
Europace 2008;10:729-735.
ABSTRACT | FULL TEXT  

Decision-making, emotional distress, and quality of life in patients affected by the recall of their implantable cardioverter defibrillator
Gibson et al.
Europace 2008;10:540-544.
ABSTRACT | FULL TEXT  

Results of a Multicenter Retrospective Implantable Cardioverter-Defibrillator Registry of Pediatric and Congenital Heart Disease Patients
Berul et al.
J Am Coll Cardiol 2008;51:1685-1691.
ABSTRACT | FULL TEXT  

Systematic Review: Implantable Cardioverter Defibrillators for Adults with Left Ventricular Systolic Dysfunction
Ezekowitz et al.
ANN INTERN MED 2007;147:251-262.
ABSTRACT | FULL TEXT  

Sudden Death Prevention With Implantable Devices
Passman and Kadish
Circulation 2007;116:561-571.
FULL TEXT  

Recalls and safety alerts affecting automated external defibrillators.
Shah and Maisel
JAMA 2006;296:655-660.
ABSTRACT | FULL TEXT  

Automated external defibrillators--device reliability and clinical benefits.
Estes
JAMA 2006;296:700-702.
FULL TEXT  

Pacemaker and ICD generator malfunctions: analysis of Food and Drug Administration annual reports.
Maisel et al.
JAMA 2006;295:1901-1906.
ABSTRACT | FULL TEXT  

Complications associated with implantable cardioverter-defibrillator replacement in response to device advisories.
Gould et al.
JAMA 2006;295:1907-1911.
ABSTRACT | FULL TEXT  

Pacemaker and ICD generator reliability: meta-analysis of device registries.
Maisel
JAMA 2006;295:1929-1934.
ABSTRACT | FULL TEXT  

Implantable Cardioverter-Defibrillators: Expanding Indications and Technologies
Goldberger and Lampert
JAMA 2006;295:809-818.
ABSTRACT | FULL TEXT  

Cost-Effectiveness of ICDs
Anderson et al.
NEJM 2006;354:205-207.
FULL TEXT  

European Heart Rhythm Association Guidance Document on cardiac rhythm management product performance.
Auricchio et al.
Europace 2006;8:313-322.
FULL TEXT  

Cardiac Resynchronization Devices: The Food and Drug Administration's Regulatory Considerations
Moynahan et al.
J Am Coll Cardiol 2005;46:2325-2328.
ABSTRACT | FULL TEXT  

Safety Issues Involving Medical Devices: Implications of Recent Implantable Cardioverter-Defibrillator Malfunctions
Maisel
JAMA 2005;294:955-958.
FULL TEXT  

Gaps, Tensions, and Conflicts in the FDA Approval Process: Implications for Clinical Practice
Deyo
J Am Board Fam Med 2004;17:142-149.
ABSTRACT | FULL TEXT  

Combining Resynchronization and Defibrillation Therapies for Heart Failure
Bradley
JAMA 2003;289:2719-2721.
FULL TEXT  

Predicting Sudden Death Risk for Heart Failure Patients in the Implantable Cardioverter-Defibrillator Age
Stevenson and Epstein
Circulation 2003;107:514-516.
FULL TEXT  

Safety of Implantable Cardiac Devices
Stanton et al.
JAMA 2002;287:839-840.
FULL TEXT  

FDA Advisories for Antiarrhythmic Devices on the Rise
Journal Watch Cardiology 2001;2001:6-6.
FULL TEXT  

Safety Alerts Involving Device Therapy for Arrhythmias
Eagle
JAMA 2001;286:843-844.
FULL TEXT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 2001 American Medical Association. All Rights Reserved.