You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT JAMA
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 302 No. 16, October 28, 2009 TABLE OF CONTENTS
  JAMA
  •  Online Features
  Letters
 This Article
 •Full text
 •PDF
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Contact me when this article is cited
 Related Content
 •Related letter
 •Similar articles in JAMA
 Topic Collections
 •Cardiovascular System
 •Quality of Care
 •Patient Safety/ Medical Error
 •Radiologic Imaging
 •Angiology
 •Computed Tomography
 •Cardiovascular Disease/ Myocardial Infarction
 •Alert me on articles by topic
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

Radiation Dose-Reduction Program for Cardiac Computed Tomography Angiography—Reply

Since this article does not have an abstract, we have provided the first 150 words of the full text and any section headings.

In Reply: Dr Torres and colleagues convey an important concern regarding the potential degradation of CCTA image quality as a consequence of decreased radiation dose. We agree that applying best-practice guidelines to decrease radiation exposure should not come at the expense of reduced scan quality.

Their suggestions of potential causes of increased numbers of poor or nondiagnostic quality scans are very reasonable. There is another potential cause that we did not quantify but might have been operative. The proportion of scans done at lower tube voltage (100 kVp) significantly increased during the course of our study (from 13% to 43%; P < .001). This had a beneficial effect on radiation dose, but due to the absorption spectrum of iodine would tend to increase the efficiency of absorption of photons at the lower voltage. The result is CT angiograms with a higher mean contrast level than scans done at 120 kVp. This . . . [Full Text of this Article]

Gilbert L. Raff, MD
graff@beaumont.edu

Kavitha M. Chinnaiyan, MD
Cardiology Division
William Beaumont Hospital
Royal Oak, Michigan

Aiden Abidov, MD, PhD
Sarver Heart Center
College of Medicine
University of Arizona
Tucson



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter     What's this?

RELATED LETTER

Radiation Dose-Reduction Program for Cardiac Computed Tomography Angiography
Felipe S. Torres, Andrew M. Crean, and Narinder Paul
JAMA. 2009;302(16):1753.
EXTRACT | FULL TEXT  